I believe you have an x13 blower motor in your air handler.
Do ecm motors have capacitors.
An ecm motor is some times referred to an a variable speed motor.
Ecm motors do not utilize capacitors external to the motor.
On that type of motor it is usually the module on the end of the motor that goes bad.
The first thing to know is that an ecm motor is brushless dc motor.
Also read about the speed torque characteristics of these motors along with its different types.
These motors are quickly outpacing other common motors as they are now dropping in price and can be used in hundreds of different applications.
Ecms in hvac systems.
A capacitor connected to a separate coil on the motor creates an alternating electric current ahead of the main phase by 90 degrees.
By zureks own work cc by sa 3 0 https commons.
The initial cost of an ecm can be high but is typically balanced by overall energy savings in the long run.
However not all ecm motors run at variable speeds and selection depends heavily upon application specifications.
Tesp system the motor still may be able to maintain airflow close to design.
What makes ecms more efficient.
This happens because the current through a capacitor leads the voltage by 90 degrees.
Here are two links to threads that discuss the issue.
In one sense this is true it does vary its rpm of the motor but only in response to changing conditions in the system.
When a furnace or air handler with an ecm is installed on a good duct coil and filtration system with static pressures within proper design parameters it can perform flawlessly.
In residential and light commercial hvac we have seen ecm variable speed x13 motors for years primarily in blower motors but sometimes even in condenser fan motors.
When considering an ecm for application in an hvac system there are several factors to keep in mind.
Although electronically commutated motors ecms are specified in efficient buildings and energy efficiency programs provide incentives for their installation i only had a cursory understanding of the difference between this technology and traditional shaded pole or permanent split capacitor type motors.
Wondering how a capacitor can be used to start a single phase motor.
But in the truest sense all it trying to do is maintain a programmed cfm.
During a motor s start up a switch connects a capacitor and a special starting coil to the.
When the blower runs is it loud.
Learn how a capacitor start induction run motor is capable of producing twice as much torque of a split phase motor.
Permanent split capacitor or psc motors are small inexpensive and popularized ac motors.
I would have hoped that the installation was done correctly based on duct work capability.
Welcome to the forums.
Usually but not always it is a thermistor inside the module that fails.
In marginal systems with higher than design static pressures for example a 5 in.
Most traditional dc motors require brushes to provide power to the motor rotor spinning part.
So if the ecm is for the indoor unit the blower motor then you most likely have undersized duct work for the size of unit.
It is actually a relatively easy repair.
To learn more read our article all about ecm motors.